Intelligent three-phase load balancing solution purpose-built for DISCOMs. Eliminate phase imbalance, reduce technical losses, and improve transformer utilization with sub-second automated switching.
The Phase Swapper continuously monitors all three phases and automatically connects the load to the most stable and balanced phase, ensuring optimal power quality.
Built-in sensors measure voltage, current, power factor, and frequency on all three phases every 1 second.
On-device edge processor runs proprietary algorithms to detect imbalance, undervoltage, or overcurrent conditions.
Solid-state relays execute phase transition in under 20ms — seamlessly re-routing load to the optimal phase without disruption.
Engineered for the demands of modern distribution networks with reliability and precision at every layer.
Continuous voltage, current, and power factor measurement across all three phases with sub-second granularity.
Intelligent load detection and automatic connection to the optimal phase based on real-time grid conditions.
Solid-state relay technology enables phase transitions in under 20ms — imperceptible to connected loads.
Proprietary algorithms distribute load evenly across phases, reducing neutral current and improving transformer efficiency.
Integrated over-voltage, under-voltage, and over-current protection with automatic load shedding on critical faults.
Seamless data relay to Chetrika Rayz cloud platform via GSM/Wi-Fi for remote monitoring and historical analysis.
On-device processing of electrical parameters with local decision-making — no cloud dependency for core switching logic.
OTA firmware upgrade capability ensures all units stay current with latest optimization algorithms and security patches.
Industrial-grade specifications designed for reliable operation in demanding field conditions.
Every Phase Swapper ships pre-configured to communicate with the Chetrika Rayz DTMS (Distribution Transformer Monitoring System) platform. Data flows automatically via cellular or Wi-Fi — no manual configuration required.
$ ./swapper --status
✓ Device CR-SW-0042 initialized
✓ Phase R: 238V / 42A / 0.94 PF
✓ Phase Y: 241V / 38A / 0.91 PF
✓ Phase B: 236V / 45A / 0.89 PF
! Imbalance detected: Y-phase underloaded
$ ./swapper --auto-balance
→ Initiating load redistribution...
✓ Load balanced: R:41A | Y:43A | B:41A
✓ Neutral current reduced 62%
Built for the real world — deployed across residential, commercial, and industrial distribution networks.
Automatically balances single-phase domestic loads across all three phases, reducing neutral current and transformer heating.
Manages dynamic load patterns in shopping centers and office buildings where phase imbalance fluctuates throughout the day.
Protects sensitive manufacturing equipment from phase-related voltage fluctuations and unbalance conditions.
Deploy Chetrika Rayz Phase Swappers across your distribution network and see immediate improvement in transformer utilization and power quality.